Main functions
The script allows you to automate the operator's work with a rotary camera.
If the operator is inactive, the script will switch the camera to one of the following modes:
- Navigating through camera presets
- Switching to preset
Installation
Installation
- Go to automation, click "Download example" and select "From file", specifying the path to the script.
- Uncheck "Enable script".
- Configure the script.
- Click "Save".
- Activate the "Enable script" checkbox.
Configuring the script
Configuring the script

- Channel - channel selection
- Work by shedule - selecting a schedule, if the schedule is not selected, the "Default mode" operation mode will be enabled

Default mode (Green or without schedule). Default mode: if the schedule is not selected, the camera will work according to the specified mode. When the schedule is selected, the camera will switch to the set operating mode when the schedule is in green.
- Alarm mode - the schedule is in the red zone
- Other mode - the schedule is in the blue zone

Default preset - specify a preset to work in Preset mode
Patrol path - patrol path in Patrol mode
Preset timeout, sec - waiting time when switching to the next preset in Patrol mode
Max random preset timeout, sec. If Preset timeout = Max random preset timeout the time when switching presets will be the same, for switching presets with random time Max random preset timeout should be more Preset timeout.

- ActiveDome / User inactivity, sec - If the camera is activated in the ActiveDome module or the PTZ is activated by the user, this parameter determines how long the script will continue to work if there are no commands from the ActiveDome module or the user is inactive.